Thermal Shock Chamber (Large Capacity)

Large format thermal shock chambers allow for testing increasingly larger samples, quantities and samples that produce high heat-load.

Today, the automotive industry accelerates electronic multi-functions. According to this trend, safety standards such as ISO26262 and IEC61508 require high environmental stress that is generated by thermal shock chambers in order to bake in greater reliability to in-vehicle equipment.

Chambers are available in 1,100-liter, 1,650-liter, and 2,200-liter models. Unlike conventional chambers, this enables thermal shock testing of large automobile parts (e.g. Li-ion battery modules, electric turbochargers, intercoolers, radiators, and inverters for vehicles), large flat panel displays, and relatively large products that could not be previously tested due to their size or weight. This is ideal for customers who need to quickly test large amounts of specimens, such as for quality inspection during the production process, or research and development projects for the defence industry.

 
 
 

Model Summary

Model TSA-1100S-W TSA-1650S-W TSA-2200S-W
Method Two-zone by means of damper switching (three-zone optional)
High-temp. exposure range +60°C to +150°C
Low-temp. exposure range -50°C to -10°C
Hot chamber max pre-heat setting temperature +180°C
Hot chamber temperature heat-up time Within 40 minutes from ambient temperature to +180°C
Cold chamber min pre-cool setting temperature -65°C
Cold chamber temperature pull-down time Within 150 minutes from ambient temperature to -65°C
Temperature recovery time Two-zone
High-temperature exposure: +85°C, 30 min.
Low-temperature exposure: -40°C, 30 min.
Power supply voltage: 200 V AC
Sensor position: upstream
Recovery rate: within 10 minutes
Specimen (iron kg) 50kg 100kg 100kg
Test area W1000mm W1500mm W2000mm
H1100mm H1100mm H1100mm
D1000mm D1000mm D1000mm
Outside dimensions W2120mm W2620mm W3120mm
H1990mm H1990mm H1990mm
D2883mm D2883mm D2972mm
Weight Approx. 3,400kg, Approx. 3700kg Approx. 3,900kg
Power supply voltage 200 V AC, 3 ohm, 3W, 50/60 Hz (Can support any power supply voltage as an option)
Maximum current value 125 180 198
Cooling water volume (25°C water) L/hr 1540 2400 2400
Cooling water volume (32°C water) L/hr 2800 4440 4440
 
Model TSA-1100H-W TSA-1650H-W TSA-2200H-W
Method Two-zone by means of damper switching (three-zone optional)
High-temp. exposure range +60°C to +180°C
Low-temp. exposure range -60°C to -10°C
Hot chamber max pre-heat setting temperature +200°C
Hot chamber temperature heat-up time Within 30 minutes from ambient temperature to +180°C
Cold chamber min pre-cool setting temperature -75°C
Cold chamber temperature pull-down time Within 150 minutes from ambient temperature to -75°C Within 80 minutes from ambient temperature to -75°C Within 90 minutes from ambient temperature to -75°C
Temperature recovery time Two-zone
High-temperature exposure: +150°C, 30 min.
Low-temperature exposure: -50°C, 30 min.
Power supply voltage: 200 V AC, 3 ohm, 3W, 50/60 Hz (Supporting any power supply voltage as an option)
Sensor position: upstream
Recovery rate: within 10 minutes
Specimen (iron kg) 50kg 100kg 100kg
Test area W1000mm W1500mm W2000mm
H1100mm H1100mm H1100mm
D1000mm D1000mm D1000mm
Outside dimensions W2120mm W2620mm W3120mm
H1990mm H1990mm H1990mm
D2883mm D2883mm D2972mm
Weight Approx. 3,500kg, Approx. 4,300kg Approx. 4,300kg
Power supply voltage 200 V AC, 3 ohm, 3W, 50/60 Hz (Can support any power supply voltage as an option)
Maximum current value 172 270 310
Cooling water volume (25°C water) L/hr 2400 4800 4800
Cooling water volume (32°C water) L/hr 4440 8880 8880
 

Large Format Thermal Shock Chambers :: Datasheet

 

Large Format Thermal Shock Chamber Videos

Previous
Previous

Thermal Shock Chamber (Air to Air)

Next
Next

Thermal Shock Chamber (Liquid to Liquid)